public static final class DescriptorProtos.FieldOptions extends GeneratedMessageV3.ExtendableMessage<DescriptorProtos.FieldOptions> implements DescriptorProtos.FieldOptionsOrBuilder
Protobuf type google.protobuf.FieldOptions
Static Fields
CTYPE_FIELD_NUMBER
public static final int CTYPE_FIELD_NUMBER
Field Value |
---|
Type | Description |
int | |
DEPRECATED_FIELD_NUMBER
public static final int DEPRECATED_FIELD_NUMBER
Field Value |
---|
Type | Description |
int | |
JSTYPE_FIELD_NUMBER
public static final int JSTYPE_FIELD_NUMBER
Field Value |
---|
Type | Description |
int | |
LAZY_FIELD_NUMBER
public static final int LAZY_FIELD_NUMBER
Field Value |
---|
Type | Description |
int | |
PACKED_FIELD_NUMBER
public static final int PACKED_FIELD_NUMBER
Field Value |
---|
Type | Description |
int | |
PARSER
public static final Parser<DescriptorProtos.FieldOptions> PARSER
UNINTERPRETED_OPTION_FIELD_NUMBER
public static final int UNINTERPRETED_OPTION_FIELD_NUMBER
Field Value |
---|
Type | Description |
int | |
WEAK_FIELD_NUMBER
public static final int WEAK_FIELD_NUMBER
Field Value |
---|
Type | Description |
int | |
Static Methods
getDefaultInstance()
public static DescriptorProtos.FieldOptions getDefaultInstance()
getDescriptor()
public static final Descriptors.Descriptor getDescriptor()
newBuilder()
public static DescriptorProtos.FieldOptions.Builder newBuilder()
newBuilder(DescriptorProtos.FieldOptions prototype)
public static DescriptorProtos.FieldOptions.Builder newBuilder(DescriptorProtos.FieldOptions prototype)
public static DescriptorProtos.FieldOptions parseDelimitedFrom(InputStream input)
public static DescriptorProtos.FieldOptions parseDelimitedFrom(InputStream input, ExtensionRegistryLite extensionRegistry)
parseFrom(byte[] data)
public static DescriptorProtos.FieldOptions parseFrom(byte[] data)
Parameter |
---|
Name | Description |
data | byte[]
|
parseFrom(byte[] data, ExtensionRegistryLite extensionRegistry)
public static DescriptorProtos.FieldOptions parseFrom(byte[] data, ExtensionRegistryLite extensionRegistry)
parseFrom(ByteString data)
public static DescriptorProtos.FieldOptions parseFrom(ByteString data)
parseFrom(ByteString data, ExtensionRegistryLite extensionRegistry)
public static DescriptorProtos.FieldOptions parseFrom(ByteString data, ExtensionRegistryLite extensionRegistry)
public static DescriptorProtos.FieldOptions parseFrom(CodedInputStream input)
public static DescriptorProtos.FieldOptions parseFrom(CodedInputStream input, ExtensionRegistryLite extensionRegistry)
public static DescriptorProtos.FieldOptions parseFrom(InputStream input)
public static DescriptorProtos.FieldOptions parseFrom(InputStream input, ExtensionRegistryLite extensionRegistry)
parseFrom(ByteBuffer data)
public static DescriptorProtos.FieldOptions parseFrom(ByteBuffer data)
parseFrom(ByteBuffer data, ExtensionRegistryLite extensionRegistry)
public static DescriptorProtos.FieldOptions parseFrom(ByteBuffer data, ExtensionRegistryLite extensionRegistry)
parser()
public static Parser<DescriptorProtos.FieldOptions> parser()
Methods
equals(Object obj)
public boolean equals(Object obj)
Compares the specified object with this message for equality. Returns true
if the given
object is a message of the same type (as defined by getDescriptorForType()
) and has
identical values for all of its fields. Subclasses must implement this; inheriting
Object.equals()
is incorrect.
Parameter |
---|
Name | Description |
obj | Object
|
Overrides
getCtype()
public DescriptorProtos.FieldOptions.CType getCtype()
The ctype option instructs the C++ code generator to use a different
representation of the field than it normally would. See the specific
options below. This option is not yet implemented in the open source
release -- sorry, we'll try to include it in a future version!
optional .google.protobuf.FieldOptions.CType ctype = 1 [default = STRING];
getDefaultInstanceForType()
public DescriptorProtos.FieldOptions getDefaultInstanceForType()
Get an instance of the type with no fields set. Because no fields are set, all getters for
singular fields will return default values and repeated fields will appear empty. This may or
may not be a singleton. This differs from the getDefaultInstance()
method of generated
message classes in that this method is an abstract method of the MessageLite
interface
whereas getDefaultInstance()
is a static method of a specific class. They return the
same thing.
getDeprecated()
public boolean getDeprecated()
Is this field deprecated?
Depending on the target platform, this can emit Deprecated annotations
for accessors, or it will be completely ignored; in the very least, this
is a formalization for deprecating fields.
optional bool deprecated = 3 [default = false];
Returns |
---|
Type | Description |
boolean | The deprecated.
|
getJstype()
public DescriptorProtos.FieldOptions.JSType getJstype()
The jstype option determines the JavaScript type used for values of the
field. The option is permitted only for 64 bit integral and fixed types
(int64, uint64, sint64, fixed64, sfixed64). A field with jstype JS_STRING
is represented as JavaScript string, which avoids loss of precision that
can happen when a large value is converted to a floating point JavaScript.
Specifying JS_NUMBER for the jstype causes the generated JavaScript code to
use the JavaScript "number" type. The behavior of the default option
JS_NORMAL is implementation dependent.
This option is an enum to permit additional types to be added, e.g.
goog.math.Integer.
optional .google.protobuf.FieldOptions.JSType jstype = 6 [default = JS_NORMAL];
getLazy()
Should this field be parsed lazily? Lazy applies only to message-type
fields. It means that when the outer message is initially parsed, the
inner message's contents will not be parsed but instead stored in encoded
form. The inner message will actually be parsed when it is first accessed.
This is only a hint. Implementations are free to choose whether to use
eager or lazy parsing regardless of the value of this option. However,
setting this option true suggests that the protocol author believes that
using lazy parsing on this field is worth the additional bookkeeping
overhead typically needed to implement it.
This option does not affect the public interface of any generated code;
all method signatures remain the same. Furthermore, thread-safety of the
interface is not affected by this option; const methods remain safe to
call from multiple threads concurrently, while non-const methods continue
to require exclusive access.
Note that implementations may choose not to check required fields within
a lazy sub-message. That is, calling IsInitialized() on the outer message
may return true even if the inner message has missing required fields.
This is necessary because otherwise the inner message would have to be
parsed in order to perform the check, defeating the purpose of lazy
parsing. An implementation which chooses not to check required fields
must be consistent about it. That is, for any particular sub-message, the
implementation must either always check its required fields, or never
check its required fields, regardless of whether or not the message has
been parsed.
optional bool lazy = 5 [default = false];
Returns |
---|
Type | Description |
boolean | The lazy.
|
getPacked()
public boolean getPacked()
The packed option can be enabled for repeated primitive fields to enable
a more efficient representation on the wire. Rather than repeatedly
writing the tag and type for each element, the entire array is encoded as
a single length-delimited blob. In proto3, only explicit setting it to
false will avoid using packed encoding.
optional bool packed = 2;
Returns |
---|
Type | Description |
boolean | The packed.
|
getParserForType()
public Parser<DescriptorProtos.FieldOptions> getParserForType()
Overrides
getSerializedSize()
public int getSerializedSize()
Get the number of bytes required to encode this message. The result is only computed on the
first call and memoized after that.
If this message requires more than Integer.MAX_VALUE bytes to encode, the return value will
be smaller than the actual number of bytes required and might be negative.
Returns |
---|
Type | Description |
int | |
Overrides
getUninterpretedOption(int index)
public DescriptorProtos.UninterpretedOption getUninterpretedOption(int index)
The parser stores options it doesn't recognize here. See above.
repeated .google.protobuf.UninterpretedOption uninterpreted_option = 999;
Parameter |
---|
Name | Description |
index | int
|
getUninterpretedOptionCount()
public int getUninterpretedOptionCount()
The parser stores options it doesn't recognize here. See above.
repeated .google.protobuf.UninterpretedOption uninterpreted_option = 999;
Returns |
---|
Type | Description |
int | |
getUninterpretedOptionList()
public List<DescriptorProtos.UninterpretedOption> getUninterpretedOptionList()
The parser stores options it doesn't recognize here. See above.
repeated .google.protobuf.UninterpretedOption uninterpreted_option = 999;
getUninterpretedOptionOrBuilder(int index)
public DescriptorProtos.UninterpretedOptionOrBuilder getUninterpretedOptionOrBuilder(int index)
The parser stores options it doesn't recognize here. See above.
repeated .google.protobuf.UninterpretedOption uninterpreted_option = 999;
Parameter |
---|
Name | Description |
index | int
|
getUninterpretedOptionOrBuilderList()
public List<? extends DescriptorProtos.UninterpretedOptionOrBuilder> getUninterpretedOptionOrBuilderList()
The parser stores options it doesn't recognize here. See above.
repeated .google.protobuf.UninterpretedOption uninterpreted_option = 999;
Returns |
---|
Type | Description |
List<? extends com.google.protobuf.DescriptorProtos.UninterpretedOptionOrBuilder> | |
getUnknownFields()
public final UnknownFieldSet getUnknownFields()
Overrides
getWeak()
For Google-internal migration only. Do not use.
optional bool weak = 10 [default = false];
Returns |
---|
Type | Description |
boolean | The weak.
|
hasCtype()
public boolean hasCtype()
The ctype option instructs the C++ code generator to use a different
representation of the field than it normally would. See the specific
options below. This option is not yet implemented in the open source
release -- sorry, we'll try to include it in a future version!
optional .google.protobuf.FieldOptions.CType ctype = 1 [default = STRING];
Returns |
---|
Type | Description |
boolean | Whether the ctype field is set.
|
hasDeprecated()
public boolean hasDeprecated()
Is this field deprecated?
Depending on the target platform, this can emit Deprecated annotations
for accessors, or it will be completely ignored; in the very least, this
is a formalization for deprecating fields.
optional bool deprecated = 3 [default = false];
Returns |
---|
Type | Description |
boolean | Whether the deprecated field is set.
|
hasJstype()
public boolean hasJstype()
The jstype option determines the JavaScript type used for values of the
field. The option is permitted only for 64 bit integral and fixed types
(int64, uint64, sint64, fixed64, sfixed64). A field with jstype JS_STRING
is represented as JavaScript string, which avoids loss of precision that
can happen when a large value is converted to a floating point JavaScript.
Specifying JS_NUMBER for the jstype causes the generated JavaScript code to
use the JavaScript "number" type. The behavior of the default option
JS_NORMAL is implementation dependent.
This option is an enum to permit additional types to be added, e.g.
goog.math.Integer.
optional .google.protobuf.FieldOptions.JSType jstype = 6 [default = JS_NORMAL];
Returns |
---|
Type | Description |
boolean | Whether the jstype field is set.
|
hasLazy()
Should this field be parsed lazily? Lazy applies only to message-type
fields. It means that when the outer message is initially parsed, the
inner message's contents will not be parsed but instead stored in encoded
form. The inner message will actually be parsed when it is first accessed.
This is only a hint. Implementations are free to choose whether to use
eager or lazy parsing regardless of the value of this option. However,
setting this option true suggests that the protocol author believes that
using lazy parsing on this field is worth the additional bookkeeping
overhead typically needed to implement it.
This option does not affect the public interface of any generated code;
all method signatures remain the same. Furthermore, thread-safety of the
interface is not affected by this option; const methods remain safe to
call from multiple threads concurrently, while non-const methods continue
to require exclusive access.
Note that implementations may choose not to check required fields within
a lazy sub-message. That is, calling IsInitialized() on the outer message
may return true even if the inner message has missing required fields.
This is necessary because otherwise the inner message would have to be
parsed in order to perform the check, defeating the purpose of lazy
parsing. An implementation which chooses not to check required fields
must be consistent about it. That is, for any particular sub-message, the
implementation must either always check its required fields, or never
check its required fields, regardless of whether or not the message has
been parsed.
optional bool lazy = 5 [default = false];
Returns |
---|
Type | Description |
boolean | Whether the lazy field is set.
|
hasPacked()
public boolean hasPacked()
The packed option can be enabled for repeated primitive fields to enable
a more efficient representation on the wire. Rather than repeatedly
writing the tag and type for each element, the entire array is encoded as
a single length-delimited blob. In proto3, only explicit setting it to
false will avoid using packed encoding.
optional bool packed = 2;
Returns |
---|
Type | Description |
boolean | Whether the packed field is set.
|
hasWeak()
For Google-internal migration only. Do not use.
optional bool weak = 10 [default = false];
Returns |
---|
Type | Description |
boolean | Whether the weak field is set.
|
hashCode()
Returns the hash code value for this message. The hash code of a message should mix the
message's type (object identity of the descriptor) with its contents (known and unknown field
values). Subclasses must implement this; inheriting Object.hashCode()
is incorrect.
Returns |
---|
Type | Description |
int | |
Overrides
internalGetFieldAccessorTable()
protected GeneratedMessageV3.FieldAccessorTable internalGetFieldAccessorTable()
Get the FieldAccessorTable for this type. We can't have the message
class pass this in to the constructor because of bootstrapping trouble
with DescriptorProtos.
Overrides
isInitialized()
public final boolean isInitialized()
Overrides
newBuilderForType()
public DescriptorProtos.FieldOptions.Builder newBuilderForType()
newBuilderForType(GeneratedMessageV3.BuilderParent parent)
protected DescriptorProtos.FieldOptions.Builder newBuilderForType(GeneratedMessageV3.BuilderParent parent)
TODO(xiaofeng): remove this together with GeneratedMessageV3.BuilderParent.
Overrides
newInstance(GeneratedMessageV3.UnusedPrivateParameter unused)
protected Object newInstance(GeneratedMessageV3.UnusedPrivateParameter unused)
Creates a new instance of this message type. Overridden in the generated code.
Overrides
toBuilder()
public DescriptorProtos.FieldOptions.Builder toBuilder()
writeTo(CodedOutputStream output)
public void writeTo(CodedOutputStream output)
Serializes the message and writes it to output
. This does not flush or close the
stream.
Overrides