Class StartManualTransferRunsRequest.TimeRange.Builder (2.0.27)

public static final class StartManualTransferRunsRequest.TimeRange.Builder extends GeneratedMessageV3.Builder<StartManualTransferRunsRequest.TimeRange.Builder> implements StartManualTransferRunsRequest.TimeRangeOrBuilder

A specification for a time range, this will request transfer runs with run_time between start_time (inclusive) and end_time (exclusive).

Protobuf type google.cloud.bigquery.datatransfer.v1.StartManualTransferRunsRequest.TimeRange

Methods

addRepeatedField(Descriptors.FieldDescriptor field, Object value)

public StartManualTransferRunsRequest.TimeRange.Builder addRepeatedField(Descriptors.FieldDescriptor field, Object value)
Parameters
NameDescription
fieldFieldDescriptor
valueObject
Returns Overrides

build()

public StartManualTransferRunsRequest.TimeRange build()
Returns

buildPartial()

public StartManualTransferRunsRequest.TimeRange buildPartial()
Returns

clear()

public StartManualTransferRunsRequest.TimeRange.Builder clear()
Returns Overrides

clearEndTime()

public StartManualTransferRunsRequest.TimeRange.Builder clearEndTime()

End time of the range of transfer runs. For example, "2017-05-30T00:00:00+00:00". The end_time must not be in the future. Creates transfer runs where run_time is in the range between start_time (inclusive) and end_time (exclusive).

.google.protobuf.Timestamp end_time = 2;

Returns

clearField(Descriptors.FieldDescriptor field)

public StartManualTransferRunsRequest.TimeRange.Builder clearField(Descriptors.FieldDescriptor field)
Parameter
NameDescription
fieldFieldDescriptor
Returns Overrides

clearOneof(Descriptors.OneofDescriptor oneof)

public StartManualTransferRunsRequest.TimeRange.Builder clearOneof(Descriptors.OneofDescriptor oneof)
Parameter
NameDescription
oneofOneofDescriptor
Returns Overrides

clearStartTime()

public StartManualTransferRunsRequest.TimeRange.Builder clearStartTime()

Start time of the range of transfer runs. For example, "2017-05-25T00:00:00+00:00". The start_time must be strictly less than the end_time. Creates transfer runs where run_time is in the range between start_time (inclusive) and end_time (exclusive).

.google.protobuf.Timestamp start_time = 1;

Returns

clone()

public StartManualTransferRunsRequest.TimeRange.Builder clone()
Returns Overrides

getDefaultInstanceForType()

public StartManualTransferRunsRequest.TimeRange getDefaultInstanceForType()
Returns

getDescriptor()

public static final Descriptors.Descriptor getDescriptor()
Returns
TypeDescription
Descriptor

getDescriptorForType()

public Descriptors.Descriptor getDescriptorForType()
Returns
TypeDescription
Descriptor
Overrides

getEndTime()

public Timestamp getEndTime()

End time of the range of transfer runs. For example, "2017-05-30T00:00:00+00:00". The end_time must not be in the future. Creates transfer runs where run_time is in the range between start_time (inclusive) and end_time (exclusive).

.google.protobuf.Timestamp end_time = 2;

Returns
TypeDescription
Timestamp

The endTime.

getEndTimeBuilder()

public Timestamp.Builder getEndTimeBuilder()

End time of the range of transfer runs. For example, "2017-05-30T00:00:00+00:00". The end_time must not be in the future. Creates transfer runs where run_time is in the range between start_time (inclusive) and end_time (exclusive).

.google.protobuf.Timestamp end_time = 2;

Returns
TypeDescription
Builder

getEndTimeOrBuilder()

public TimestampOrBuilder getEndTimeOrBuilder()

End time of the range of transfer runs. For example, "2017-05-30T00:00:00+00:00". The end_time must not be in the future. Creates transfer runs where run_time is in the range between start_time (inclusive) and end_time (exclusive).

.google.protobuf.Timestamp end_time = 2;

Returns
TypeDescription
TimestampOrBuilder

getStartTime()

public Timestamp getStartTime()

Start time of the range of transfer runs. For example, "2017-05-25T00:00:00+00:00". The start_time must be strictly less than the end_time. Creates transfer runs where run_time is in the range between start_time (inclusive) and end_time (exclusive).

.google.protobuf.Timestamp start_time = 1;

Returns
TypeDescription
Timestamp

The startTime.

getStartTimeBuilder()

public Timestamp.Builder getStartTimeBuilder()

Start time of the range of transfer runs. For example, "2017-05-25T00:00:00+00:00". The start_time must be strictly less than the end_time. Creates transfer runs where run_time is in the range between start_time (inclusive) and end_time (exclusive).

.google.protobuf.Timestamp start_time = 1;

Returns
TypeDescription
Builder

getStartTimeOrBuilder()

public TimestampOrBuilder getStartTimeOrBuilder()

Start time of the range of transfer runs. For example, "2017-05-25T00:00:00+00:00". The start_time must be strictly less than the end_time. Creates transfer runs where run_time is in the range between start_time (inclusive) and end_time (exclusive).

.google.protobuf.Timestamp start_time = 1;

Returns
TypeDescription
TimestampOrBuilder

hasEndTime()

public boolean hasEndTime()

End time of the range of transfer runs. For example, "2017-05-30T00:00:00+00:00". The end_time must not be in the future. Creates transfer runs where run_time is in the range between start_time (inclusive) and end_time (exclusive).

.google.protobuf.Timestamp end_time = 2;

Returns
TypeDescription
boolean

Whether the endTime field is set.

hasStartTime()

public boolean hasStartTime()

Start time of the range of transfer runs. For example, "2017-05-25T00:00:00+00:00". The start_time must be strictly less than the end_time. Creates transfer runs where run_time is in the range between start_time (inclusive) and end_time (exclusive).

.google.protobuf.Timestamp start_time = 1;

Returns
TypeDescription
boolean

Whether the startTime field is set.

internalGetFieldAccessorTable()

protected GeneratedMessageV3.FieldAccessorTable internalGetFieldAccessorTable()
Returns
TypeDescription
FieldAccessorTable
Overrides

isInitialized()

public final boolean isInitialized()
Returns
TypeDescription
boolean
Overrides

mergeEndTime(Timestamp value)

public StartManualTransferRunsRequest.TimeRange.Builder mergeEndTime(Timestamp value)

End time of the range of transfer runs. For example, "2017-05-30T00:00:00+00:00". The end_time must not be in the future. Creates transfer runs where run_time is in the range between start_time (inclusive) and end_time (exclusive).

.google.protobuf.Timestamp end_time = 2;

Parameter
NameDescription
valueTimestamp
Returns

mergeFrom(StartManualTransferRunsRequest.TimeRange other)

public StartManualTransferRunsRequest.TimeRange.Builder mergeFrom(StartManualTransferRunsRequest.TimeRange other)
Parameter Returns

mergeFrom(CodedInputStream input, ExtensionRegistryLite extensionRegistry)

public StartManualTransferRunsRequest.TimeRange.Builder mergeFrom(CodedInputStream input, ExtensionRegistryLite extensionRegistry)
Parameters
NameDescription
inputCodedInputStream
extensionRegistryExtensionRegistryLite
Returns Overrides Exceptions
TypeDescription
IOException

mergeFrom(Message other)

public StartManualTransferRunsRequest.TimeRange.Builder mergeFrom(Message other)
Parameter
NameDescription
otherMessage
Returns Overrides

mergeStartTime(Timestamp value)

public StartManualTransferRunsRequest.TimeRange.Builder mergeStartTime(Timestamp value)

Start time of the range of transfer runs. For example, "2017-05-25T00:00:00+00:00". The start_time must be strictly less than the end_time. Creates transfer runs where run_time is in the range between start_time (inclusive) and end_time (exclusive).

.google.protobuf.Timestamp start_time = 1;

Parameter
NameDescription
valueTimestamp
Returns

mergeUnknownFields(UnknownFieldSet unknownFields)

public final StartManualTransferRunsRequest.TimeRange.Builder mergeUnknownFields(UnknownFieldSet unknownFields)
Parameter
NameDescription
unknownFieldsUnknownFieldSet
Returns Overrides

setEndTime(Timestamp value)

public StartManualTransferRunsRequest.TimeRange.Builder setEndTime(Timestamp value)

End time of the range of transfer runs. For example, "2017-05-30T00:00:00+00:00". The end_time must not be in the future. Creates transfer runs where run_time is in the range between start_time (inclusive) and end_time (exclusive).

.google.protobuf.Timestamp end_time = 2;

Parameter
NameDescription
valueTimestamp
Returns

setEndTime(Timestamp.Builder builderForValue)

public StartManualTransferRunsRequest.TimeRange.Builder setEndTime(Timestamp.Builder builderForValue)

End time of the range of transfer runs. For example, "2017-05-30T00:00:00+00:00". The end_time must not be in the future. Creates transfer runs where run_time is in the range between start_time (inclusive) and end_time (exclusive).

.google.protobuf.Timestamp end_time = 2;

Parameter
NameDescription
builderForValueBuilder
Returns

setField(Descriptors.FieldDescriptor field, Object value)

public StartManualTransferRunsRequest.TimeRange.Builder setField(Descriptors.FieldDescriptor field, Object value)
Parameters
NameDescription
fieldFieldDescriptor
valueObject
Returns Overrides

setRepeatedField(Descriptors.FieldDescriptor field, int index, Object value)

public StartManualTransferRunsRequest.TimeRange.Builder setRepeatedField(Descriptors.FieldDescriptor field, int index, Object value)
Parameters
NameDescription
fieldFieldDescriptor
indexint
valueObject
Returns Overrides

setStartTime(Timestamp value)

public StartManualTransferRunsRequest.TimeRange.Builder setStartTime(Timestamp value)

Start time of the range of transfer runs. For example, "2017-05-25T00:00:00+00:00". The start_time must be strictly less than the end_time. Creates transfer runs where run_time is in the range between start_time (inclusive) and end_time (exclusive).

.google.protobuf.Timestamp start_time = 1;

Parameter
NameDescription
valueTimestamp
Returns

setStartTime(Timestamp.Builder builderForValue)

public StartManualTransferRunsRequest.TimeRange.Builder setStartTime(Timestamp.Builder builderForValue)

Start time of the range of transfer runs. For example, "2017-05-25T00:00:00+00:00". The start_time must be strictly less than the end_time. Creates transfer runs where run_time is in the range between start_time (inclusive) and end_time (exclusive).

.google.protobuf.Timestamp start_time = 1;

Parameter
NameDescription
builderForValueBuilder
Returns

setUnknownFields(UnknownFieldSet unknownFields)

public final StartManualTransferRunsRequest.TimeRange.Builder setUnknownFields(UnknownFieldSet unknownFields)
Parameter
NameDescription
unknownFieldsUnknownFieldSet
Returns Overrides