Class InterconnectDiagnosticsLinkOpticalPower (0.8.0)

InterconnectDiagnosticsLinkOpticalPower(
    mapping=None, *, ignore_unknown_fields=False, **kwargs
)

Attributes

NameDescription
state google.cloud.compute_v1.types.InterconnectDiagnosticsLinkOpticalPower.State
The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold. - LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold. This field is a member of oneof_ _state.
value float
Value of the current receiving or transmitting optical power, read in dBm. Take a known good optical value, give it a 10% margin and trigger warnings relative to that value. In general, a -7dBm warning and a -11dBm alarm are good optical value estimates for most links. This field is a member of oneof_ _value.

Classes

State

State(value)

The status of the current value when compared to the warning and alarm levels for the receiving or transmitting transceiver. Possible states include: - OK: The value has not crossed a warning threshold.

  • LOW_WARNING: The value has crossed below the low warning threshold. - HIGH_WARNING: The value has crossed above the high warning threshold. - LOW_ALARM: The value has crossed below the low alarm threshold. - HIGH_ALARM: The value has crossed above the high alarm threshold.