public sealed class Form.Types.Parameter.Types.FillBehavior : IMessage<Form.Types.Parameter.Types.FillBehavior>, IEquatable<Form.Types.Parameter.Types.FillBehavior>, IDeepCloneable<Form.Types.Parameter.Types.FillBehavior>, IBufferMessage, IMessage
Reference documentation and code samples for the Dialogflow v3 API class Form.Types.Parameter.Types.FillBehavior.
Configuration for how the filling of a parameter should be handled.
Implements
IMessageFormTypesParameterTypesFillBehavior, IEquatableFormTypesParameterTypesFillBehavior, IDeepCloneableFormTypesParameterTypesFillBehavior, IBufferMessage, IMessageNamespace
GoogleCloudGoogle.Cloud.DialogflowGoogle.Cloud.Dialogflow.CxV3Assembly
Google.Cloud.Dialogflow.Cx.V3.dll
Constructors
FillBehavior()
public FillBehavior()
FillBehavior(FillBehavior)
public FillBehavior(Form.Types.Parameter.Types.FillBehavior other)
Parameter | |
---|---|
Name | Description |
other | FormTypesParameterTypesFillBehavior |
Properties
InitialPromptFulfillment
public Fulfillment InitialPromptFulfillment { get; set; }
Required. The fulfillment to provide the initial prompt that the agent can present to the user in order to fill the parameter.
Property Value | |
---|---|
Type | Description |
Fulfillment |
RepromptEventHandlers
public RepeatedField<EventHandler> RepromptEventHandlers { get; }
The handlers for parameter-level events, used to provide reprompt for the parameter or transition to a different page/flow. The supported events are:
sys.no-match-<N>
, where N can be from 1 to 6sys.no-match-default
sys.no-input-<N>
, where N can be from 1 to 6sys.no-input-default
sys.invalid-parameter
initial_prompt_fulfillment
provides the first prompt for the
parameter.
If the user's response does not fill the parameter, a
no-match/no-input event will be triggered, and the fulfillment
associated with the sys.no-match-1
/sys.no-input-1
handler (if
defined) will be called to provide a prompt. The
sys.no-match-2
/sys.no-input-2
handler (if defined) will respond to
the next no-match/no-input event, and so on.
A sys.no-match-default
or sys.no-input-default
handler will be used
to handle all following no-match/no-input events after all numbered
no-match/no-input handlers for the parameter are consumed.
A sys.invalid-parameter
handler can be defined to handle the case
where the parameter values have been invalidated
by webhook. For
example, if the user's response fill the parameter, however the
parameter was invalidated by webhook, the fulfillment associated with
the sys.invalid-parameter
handler (if defined) will be called to
provide a prompt.
If the event handler for the corresponding event can't be found on the
parameter, initial_prompt_fulfillment
will be re-prompted.
Property Value | |
---|---|
Type | Description |
RepeatedFieldEventHandler |