This document describes how to configure Google Distributed Cloud to provide multiple network interfaces, multi-NIC, for your pods. The multi-NIC for pods feature can help separate control plane traffic from data plane traffic, creating isolation between planes. Additional network interfaces also enable multicast capability for your pods. Multi-NIC for pods is supported for user clusters, hybrid clusters, and standalone clusters. It is not allowed for admin type clusters.
Network plane isolation is important for systems using network functions virtualizations (NFVs), such as software-defined networking in a wide area network (SD-WAN), a cloud access security broker (CASB), and next-generation firewalls (NG-FWs). These types of NFVs rely on access to multiple interfaces to keep the management and data planes separate, while running as containers.
The multiple network interface configuration supports associating network interfaces with node pools, which can provide performance benefits. Clusters can contain a mix of node types. When you group high-performance machines into one node pool, you can add additional interfaces to the node pool to improve traffic flow.
Set up multiple network interfaces
Generally, there are three steps to set up multiple network interfaces for your pods:
Enable multi-NIC for your cluster with the
multipleNetworkInterfaces
field in the cluster custom resource.Specify network interfaces with
NetworkAttachmentDefinition
custom resources.Assign network interfaces to pods with the
k8s.v1.cni.cncf.io/networks
annotation.
Additional information is provided to help you configure and use the multi-NIC feature in a way that best suits your networking requirements.
Enable multi-NIC
Enable multi-NIC for your pods by adding the multipleNetworkInterfaces
field
to the clusterNetwork
section of the cluster custom resource and setting it to
true
.
...
clusterNetwork:
multipleNetworkInterfaces: true
pods:
cidrBlocks:
- 192.168.0.0/16
services:
cidrBlocks:
- 10.96.0.0/20
...
Specify network interfaces
Use NetworkAttachmentDefinition
custom resources to specify additional network
interfaces. The NetworkAttachmentDefinition
custom resources correspond to the
networks that are available for your pods. You can specify the custom resources
within the cluster configuration, as shown in the following example, or you can
create the NetworkAttachmentDefinition
custom resources directly.
---
apiVersion: baremetal.cluster.gke.io/v1
kind: Cluster
metadata:
name: my-cluster
namespace: cluster-my-cluster
spec:
type: user
clusterNetwork:
multipleNetworkInterfaces: true
...
---
apiVersion: "k8s.cni.cncf.io/v1"
kind: NetworkAttachmentDefinition
metadata:
name: gke-network-1
namespace: cluster-my-cluster
spec:
config: '{
"cniVersion":"0.3.0",
"type": "ipvlan",
"master": "enp2342", # defines the node interface that this pod interface would
map to.
"mode": "l2",
"ipam": {
"type": "whereabouts",
"range": "172.120.0.0/24"
}
}'
---
apiVersion: "k8s.cni.cncf.io/v1"
kind: NetworkAttachmentDefinition
metadata:
name: gke-network-2
namespace: cluster-my-cluster
spec:
config: '{
"cniVersion":"0.3.0",
"type": "macvlan",
"mode": "bridge",
"master": "vlan102",
"ipam": {
"type": "static",
"addresses": [
{
"address": "10.10.0.1/24",
"gateway": "10.10.0.254"
}
],
"routes": [
{ "dst": "192.168.0.0/16", "gw": "10.10.5.1" }
]
}
}'
When you specify the NetworkAttachmentDefinition
custom resource in your
cluster configuration file, Google Distributed Cloud uses this name to control the
NetworkAttachmentDefinition
custom resource after cluster creation.
Google Distributed Cloud treats this custom resource inside the cluster namespace
as the source of truth and reconciles it to the default
namespace of the
target cluster.
The following diagram illustrates how Google Distributed Cloud reconciles
NetworkAttachmentDefinition
custom resources from the cluster-specific
namespace to the default
namespace.
Although it is optional, we recommend that you specify
NetworkAttachmentDefinition
custom resources this way, during cluster
creation. User clusters benefit the most when you specify the custom resources
during cluster creation, because you can then control the
NetworkAttachmentDefinition
custom resources from the admin cluster.
If you choose not to specify NetworkAttachmentDefinition
custom resources
during cluster creation, you can add NetworkAttachmentDefinition
custom
resources directly to an existing target cluster. Google Distributed Cloud
reconciles NetworkAttachmentDefinition
custom resources defined in the cluster
namespace. Reconciliation also happens upon deletion. When a
NetworkAttachmentDefinition
custom resource is removed from a cluster
namespace, Google Distributed Cloud removes the custom resource from the target
cluster.
Assign network interfaces to a pod
Use the k8s.v1.cni.cncf.io/networks
annotation to assign one or more network
interfaces to a pod. Each network interface is specified with a namespace and
the name of a NetworkAttachmentDefinition
custom resource, separated by a
forward slash (/
).
---
apiVersion: v1
kind: Pod
metadata:
name: samplepod
annotations:
k8s.v1.cni.cncf.io/networks: NAMESPACE/NAD_NAME
spec:
containers:
...
Replace the following:
NAMESPACE
: the namespace. Usedefault
for the default namespace, which is standard. See Security concerns for an exception.NAD_NAME
: the name of theNetworkAttachmentDefinition
custom resource.
Use a comma-separated list to specify multiple network interfaces.
In the following example, two network interfaces are assigned to the samplepod
Pod. The network interfaces are specified by names of two
NetworkAttachmentDefinition
custom resources, gke-network-1
and
gke-network-2
, in the default namespace of the target cluster.
---
apiVersion: v1
kind: Pod
metadata:
name: samplepod
annotations:
k8s.v1.cni.cncf.io/networks: default/gke-network-1,default/gke-network-2
spec:
containers:
...
Restrict network interfaces to a NodePool
Use the k8s.v1.cni.cncf.io/nodeSelector
annotation to specify the pool of
nodes for which a NetworkAttachmentDefinition
custom resource is valid.
Google Distributed Cloud forces any pods that reference this custom resource to be
deployed on those specific nodes. In the following example,
Google Distributed Cloud forces deployment of all pods that are assigned the
gke-network-1
network interface to the multinicNP
NodePool.
Google Distributed Cloud labels a NodePool with the
baremetal.cluster.gke.io/node-pool
label accordingly.
apiVersion: "k8s.cni.cncf.io/v1"
kind: NetworkAttachmentDefinition
metadata:
annotations:
k8s.v1.cni.cncf.io/nodeSelector: baremetal.cluster.gke.io/node-pool=multinicNP
name: gke-network-1
spec:
...
You are not limited to using the standard labels. You can create your own,
custom pools from the cluster nodes by applying a custom label to those nodes.
Use the kubectl label nodes
command to apply a custom label:
kubectl label nodes NODE_NAME LABEL_KEY=LABEL_VALUE
Replace the following:
NODE_NAME
: the name of the Node you are labeling.LABEL_KEY
: the key to use for your label.LABEL_VALUE
: the label name.
Once the node is labeled, apply the
baremetal.cluster.gke.io/label-taint-no-sync
annotation on that node to
prevent Google Distributed Cloud from reconciling the labels. Use the
kubectl get nodes --show-labels
command to verify if a node is labeled.
Security concerns
A NetworkAttachmentDefinition
custom resource provides full access to a
network, so cluster administrators must be cautious about providing create,
update, or delete access to other users. If a given
NetworkAttachmentDefinition
custom resource has to be isolated, it can be
placed in a non-default namespace, where only the pods from that namespace can
access it. To reconcile NetworkAttachmentDefinition
custom resources specified
in the cluster configuration file, they are always placed in the default
namespace.
In the following diagram, pods from the default
namespace can't access the
network interface in the privileged
namespace.
Supported CNI plugins
This section lists the
CNI plugins
supported by the multi-NIC feature for Google Distributed Cloud. Use only the
following plugins when specifying a NetworkAttachmentDefinition
custom
resource.
Interface creation:
ipvlan
macvlan
bridge
sriov
Meta plugins:
portmap
sbr
tuning
IPAM plugins:
host-local
static
whereabouts
Route configuration
A pod with one or more assigned NetworkAttachmentDefinition
custom resources
has multiple network interfaces. By default, the routing table in this situation
is extended with the locally available additional interfaces from assigned
NetworkAttachmentDefinition
custom resources only. The default gateway is
still configured to use the master/default interface of the pod, eth0
.
You can modify this behavior by using the following CNI plugins:
sbr
static
whereabouts
For example, you might want all traffic to go through the default gateway, the default interface. However, some specific traffic goes over one of the non-default interfaces. Traffic can be difficult to disambiguate based on destination IP (normal routing), because the same endpoint is available over both the interface types. In this case, source-based routing (SBR) can help.
SBR plugin
The sbr
plugin gives the application control over routing decisions. The
application controls what is used as the source IP address of the connection it
establishes. When the application chooses to use the
NetworkAttachmentDefinition
custom resource's IP address for its source IP,
packets land in the additional routing table sbr
has set up. The sbr
routing
table establishes the NetworkAttachmentDefinition
custom resource's interface
as the default gateway. The default gateway IP inside that table is controlled
with the gateway
field inside whereabouts
or static
plugins. Provide the
sbr
plugin as a chained plugin. For more information about the sbr
plugin,
including usage information, see
Source-based routing plugin.
The following example shows "gateway":"21.0.111.254"
set in whereabouts
, and
sbr
set as chained plugin after ipvlan
:
# ip route
default via 192.168.0.64 dev eth0 mtu 1500
192.168.0.64 dev eth0 scope link
# ip route list table 100
default via 21.0.111.254 dev net1
21.0.104.0/21 dev net1 proto kernel scope link src 21.0.111.1
Static and whereabouts plugins
The whereabouts
plugin is basically an extension of the static
plugin and
these two share the routing configuration. For a configuration example, see
static IP address management plugin.
You can define a gateway and route to add to the pod's routing table. You can't,
however, modify the default gateway of the pod in this way.
The following example shows the addition of
"routes": [{ "dst": "172.31.0.0/16" }]
in the NetworkAttachmentDefinition
custom resource:
# ip route
default via 192.168.0.64 dev eth0 mtu 1500
172.31.0.0/16 via 21.0.111.254 dev net1
21.0.104.0/21 dev net1 proto kernel scope link src 21.0.111.1
192.168.0.64 dev eth0 scope link
Configuration examples
This section illustrates some of the common network configurations supported by the multi-NIC feature.
Single network attachment used by multiple pods
Multiple network attachments used by single pod
Multiple network attachments pointing to same interface used by single pod
Same network attachment used multiple times by single pod
Troubleshoot
If additional network interfaces are misconfigured, the pods to which they are assigned don't start. This section highlights how to find information for troubleshooting issues with the multi-NIC feature.
Check pod events
Multus
reports failures through Kubernetes pod events. Use the following
kubectl describe
command to view events for a given pod:
kubectl describe pod POD_NAME
Check logs
For each node, you can find Whereabouts and Multus logs at the following locations:
/var/log/whereabouts.log
/var/log/multus.log
Review pod interfaces
Use the kubectl exec
command to check your pod interfaces. Once the
NetworkAttachmentDefinition
custom resources are successfully applied, the pod
interfaces look like the following output:
$ kubectl exec samplepod-5c6df74f66-5jgxs -- ip a
1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state UNKNOWN group default qlen 1000
link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00
inet 127.0.0.1/8 scope host lo
valid_lft forever preferred_lft forever
2: net1: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UNKNOWN group default
link/ether 00:50:56:82:3e:f0 brd ff:ff:ff:ff:ff:ff
inet 21.0.103.112/21 scope global net1
valid_lft forever preferred_lft forever
38: eth0@if39: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP group default
link/ether 36:23:79:a9:26:b3 brd ff:ff:ff:ff:ff:ff link-netnsid 0
inet 192.168.2.191/32 scope global eth0
valid_lft forever preferred_lft forever
Get pod status
Use the kubectl get
to retrieve the network status for a given pod:
kubectl get pods POD_NAME -oyaml
Here's a sample output that shows the status of a pod with multiple networks:
apiVersion: v1
kind: Pod
metadata:
annotations:
k8s.v1.cni.cncf.io/network-status: |-
[{
"name": "",
"interface": "eth0",
"ips": [
"192.168.1.88"
],
"mac": "36:0e:29:e7:42:ad",
"default": true,
"dns": {}
},{
"name": "default/gke-network-1",
"interface": "net1",
"ips": [
"21.0.111.1"
],
"mac": "00:50:56:82:a7:ab",
"dns": {}
}]
k8s.v1.cni.cncf.io/networks: gke-network-1